Carpentry
Seating: 1937 fixed, continental-style theater seats; (main floor: 1205 fixed seats; mezzanine: 732 fixed); 60 additional chairs may be placed on the orchestra lift when set to house floor height. 43 tech kills can be added as portable chairs. See seating chart.
Handicap seating: main floor: 6 permanent wheelchair positions house left; ; mezzanine: 4 permanent wheelchair positions. See seating chart.
Total Capacity: Adding together the fixed seats, optional pit chairs, tech kills and wheelchair spaces yields a total mapped capacity of 2050. Subtracting 20 house holds, per lease agreement, yields a maximum sellable potential of 2030, depending on production requirements. See seating chart.
Stage Dimensions (also see drawings): Proscenium 60’ x 30’; torms adjustable inward to 45’; Stage is 51’ deep, apron below plaster line is 3’6” to pit edge, raised pit surface extends apron an additional 13’.
Wing space: 30’ SR and SL.
Grid height: 75’ to bottom of grid.
Orchestra lift: 46’ x 13’, hydraulic platform, maximum load 83,000 lbs., adjustable from stage level to 9’ below stage level, add 12’ of additional fixed floor depth at lowered playing levels.
Stage height: 3’2” above seating floor.
Stage floor: maple, stained with ebony and in excellent condition. There are no traps on the stage. All fasteners must be pre-drilled before installation and there is a per hole charge.
House Draperies (goods): Grand: maroon, guillotine or traverse, traveler cord located SR, line set 3.
Grand Teaser: maroon, adjustable trim, line set 1; Legs: 4 pair, black velour, 17’ wide x 37’ high, no fullness.
Borders: black velour, 17’ wide x 10’ high, 20 pieces (4 borders), no fullness.
Traveler: black velour, sewn fullness, actuated SR, line set 56.
Cycs: 2 white, 70’ wide x 30’ high; 1 black sharks tooth, 70’ wide x 30’ high, good condition.
Movie Screen: perforated, 45’ wide x 25’ high, line set 2.
Black Out Curtain: full stage, no fullness, line set 84.
Line Set Data (see schedule for immovable pieces, etc.): Working heights: high trim, 71’; low trim, 3’6”. Electrics: high trim, 50’; low trim, 3’6”.
Battens: 48 - 76’ battens; 1 1/2” schd. 40 pipe; on 7” centers; 4 - electrics; 3 - permanent draperies; 2 leg battens.
Lift lines per batten: 7; type: all line sets are single purchase.
Arbor Capacity: 1400 lbs. per batten; 2800 lbs. per electric.
Available Weight: 30,000 lbs, available at loading bridge and floor.
Loading Gallery: SL, 66’ above stage.
Pin Rail: SL & SR, 36’ above stage (used for spot lines).
Locking Rail: SL, at stage level.
Support Areas (also see floor plan):
Crossover: external, behind stage, at stage level, 4” wide.
Access: Load-in, upstage right; main entry, mid stage right
Loading dock: 48” high, adjustable ramp, loads through Scene Shop at stage level.
Dressing Rooms (also see wardrobe): 1st floor (stage level) accessed from SR, 2 - 6–8 person, 1 - single person. 2nd floor, 2 - chorus dressing rooms, 2 - single person.
Green Room: Green room located off-SR, often used as production office.
Scene Shop: 52’ x 33’ space for storage, located off-SR.
Storage: Limited upstage storage: this area is mainly the Morrison Center storage area for equipment. (large orchestra shell, lighting equipment, etc.).
Electrical
Power: Located on stage right wall.
2 - 400A service, 120/208V, 3-phase
1 - 200A service, 120/208V, 3-phase
Each service terminates in a female, 5-wire PosiLock panel*.
Adaptors to female CamLock #1016 are available.
* Otherwise, a licensed electrician must connect/disconnect pigtails, 14-day prior notice is required.
Dimmers: 253 - 2.4 kW ETC Sensor Dimmers; 7 - 6 kW ETC Sensor Dimmers
Control System: ETC Obsession II 750 SPS located in light booth at rear of orchestra seating. Remote focus capability on stage only. DMX outputs located SL, SR, 1st catwalk, 2nd catwalk.
DMX 1 controls channels 1-306
DMX 2 controls channels 350-750
House Light Control: ETC Unison system. Controls located at SM Station (SR), manual or electronic control.
Circuits: 253 - 20A circuits; 7 - 50A circuits
Front of House Transfer (number of circuits - location):
15 - 3rd catwalk 5 - box boom HL
18 - 2nd catwalk 5 - box boom HR
12 - 1st catwalk 5 - SR cove
2 - rear of orch pit (SL) 5 - SL cove
2 - rear of orch pit (SR) All transfer circuits are 20 amp, all are 3-pin stage connectors.
FOH Positions: 1st catwalk position: 85 degrees, 32’-00”
2nd catwalk position: 45 degrees, 52’-00”
3rd catwalk position: 30 degrees, 68’-00”
Front of House Inventory:
35 - 14° Source Four 575W 2nd catwalk & 35 - 10° units 3rd catwalk.
16 - 8 x 13 Ellipsoidial's 1000W (8 each) HL and HR upper box booms
Stage Inventory:
48 - 19° Source Four 575W
48 - 26° Source Four 575W
48 - 36° Source Four 575W
8 - 50° Source Four 575W
42 - 8” Fresnels 1000W
60 - Source Four Par 575W
10 - 4–cell Far Cycs 1000W
18 - 6’ 4–color Borders 500W
Follow Spots: 2 - Lycian 1290XLT 2000W Xenon lamp; 2 - Strong Super Troupers, 1600W xenon lamp, located in follow
spot bay above mezzanine level, throw distance to proscenium: 143’–00”
Misc: 60 - A-size pattern holders; 8 - 12’–00” booms (light trees)
48 - side arms; 4 - 50A breakouts
Cable: 27 - 50 ft. 30 - 25 ft. 20 - 15 ft. 30 - 10 ft.
Video Projection: 1 - Eiki LC-X5A, 6,500 Lumen video proj.; 7.25-12.38 long-throw lens, 1.4-1.8 short-throw lens; 1 - 10.5’ x 14’ Front/Rear Screen w/ Dress Kit
Notes: Instruments are rented per unit. We do not stock gels.
Audio
POWER: Stage Right: 1–200A, 120/208V, 3-phase disconnect; 5–20A, 120V duplex outlets (proscenium wall).
Stage Left: 1–60A, 120/208V, 3-phase disconnect; 4–20A, 120V duplex outlets (proscenium wall).
STAGE AUDIO LINES (to house patchbay): SL proscenium wall: 26 XLR input/output lines (hardwire split), 8 XLR output lines; 16 XLR input wall box (NO split), Stg. Right. Seventy-five various other inputs throughout the facility. All inputs patchable at console through 1/4” RTS patchbay.
HOUSE CONSOLE: DDA Q-2: 40 mic inputs; 8 stereo line inputs; 8 stereo subgroups; 4 FB, 4 AUX sends/channel;
6 stereo matrix outputs available; true Left-Center-Right (LCR) main outputs. (master section mid-console).
EFFECTS AND PROCESSING: 2 – TC Electronic M-one XL digital reverb; 8-channels Presonus CL44 comp/limiter; 8-channels Presonus GTX44 noise gate; 1 – DBX 160X comp/limit er; 1 – Aphex single-channel Compellor comp/limiter; 1 – Valley People Dynamite-II, 2-ch. comp/limiter/gate; 1 – SPL Vitalizer.
FIXED SPEAKER SYSTEMS: Mono System – horn-loaded, flown center cluster, Lows – two CL&S cabinets w/15” JBL 2226, Mid – CL&S M4; High – coaxially-mounted TAD 4001 driver/EV HP-940 horn; balcony fill – 2 Ramsa WS-A200; proscenium front fill – delayed, 8” coaxial, horizontal line array, extending across pit wall. 5-pc. Meyer UPM1P pit fill system; Stereo System – main L/R is a flown pair of JBL 4892s on each side of proscenium; 2 delayed pairs of OAP coaxial satellite cabinets provide excellent stereo coverage to entire house. Crown IQ-controlled.
PORTABLE SPEAKERS: Stage Monitoring from house console only. We DO NOT have a separate monitor console. 4 speaker-level circuits are located around stage; 4 stereo (8-mono) patchable line-level circuits stage left.
4 – KV2 EX-12 powered speakers; 2 – TC Helicon VM-300 powered spot monitors;
2 – EV 1202 floor monitor cabinets.; 2 – EV 12-2A floor monitor cabinets.; 4 – K&K 15” 3-way (huge!) floor monitor cabinets (2 are stand-mounted for use as side fills); 3 – EAW JF-80 (usually used upstage or overhead).
PRODUCTION COMMUNICATIONS: 2-ch. ClearCom. House production paging overrides program to dressing rooms.
INVENTORY: see PDF package.
Properties
Orchestra Pit: Lift surface measures 14’x 48’;
- hydraulic, maximum load 83,000 lbs.;
- adjustable from stage level to 9’ below stage level;
- pit floor dimension (at minus 9’) is 24’6” x 58’;
- comprises majority of apron downstage of proscenium.
Orchestra Shell: Secoa-designed, rolling wall units combine with two suspended, folding ceiling units (with built-in down-light, on motorized winches) upstage of plaster line. These couple with the apron and permanent sound clouds downstage of proscenium to form the complete orchestral environment. Shell ceiling is redwood paneled, walls are off-white with oak trim.
Downstage apron width: 68’
Rear shell width: 34’
Depth of shell and apron: 41’
Note: deployed ceiling prevents use all line sets above shell.
Chairs: 85 - straight–back chairs black vinyl-covered.
Music Stands: 20 - black Manhasset
Music Stand Lights: 20 - adjustable, music stand clip lights
Risers: 4 - 6’ x 8’ carpeted (16”/24” height)
3 - 4’ x 8’ plywood top/1” steel parallel frame (18” - 30” height)
12 - 4’ x 8’ plywood top/1” steel parallel frame (30” - 46” height)
4 - 4’ x 4’ plywood top/1” steel parallel frame (30” - 46” height)
Lectern: 1 - non-adjustable, oak
Tables: 4 - 6’ x 2’6”; 4 - 8’ x 2’6”
Pianos: 2 - Steinway 9’ concert grand, model D, ebony satin finish, tuned to A440; maintained by Mr. Paul Schiller, factory-trained Steinway technician, 1-800 281-5549.
1 - Yamaha DX7
Dance Floor: 8 - 50’-wide black sections; additional flooring available..
Wardrobe
Dressing Rooms:
Main Floor (stage level):
Two - 6–8 person dressing rooms, located 10 and 15 paces from SR entrance door.
One - single person dressing room, located 26 paces from SR entrance door.
Second Floor: 26 paces from SR door to stairs (29 stair steps), then another 10-15 paces to rooms.
Two - 25–30 person (chorus) dressing rooms.
Two - 1–2 person dressing rooms (carpeted).
Staircase located across hallway from freight elevator. All rooms have showers, sinks and lighted mirrors.
Wardrobe Area: 3rd floor, access is by freight elevator or stairs. (Elevator 6’ x 7’ x 7’) Room is 30’ x 12’
Ironing: 1Black & Decker Professional; Ironing Boards: 3
Steamer: 1 - Jiffy J4000
Washer and Dryer: 2 sets, consumer-type.
Note: If company carries a washer or dryer, these can be hooked-up in scene shop (by Center’s permanent staff only).
Rolling Racks: 6 - folding, 4 - straight
Quick Change Booths (Pipe & Drape style): 27 - 5’ x 8’ Commando-cloth panels; 12 - uprights & bases